An introduction to the heat component of the air vents

  1. The taste of self-induction low temperature componentsSelf-induction temperature type components is mainly used for central air conditioning, ventilation, air supply system can control the tuyere, diffuser, ball screw tuyere, wind flow and tuyere wind, uniform air automatic adjustment, replacing the conventional manual or electric control of cumbersome, this element does not require electricity or other additional equipment in use, easy to use, is the existing optimal scheme of central air conditioning temperature, air volume control, and has low price, easy installation and use, small volume, long service life, safe and reliable, and low failure rate. In the actual use industry and terminal customer consistent high praise.Working principle of the 2.Sealed in a casing thermal expansion of the material, after exposure to the set temperature sensing, expansion, under the influence of inflation pressure, with components in rubber seal putter move to drive components. Heat energy into mechanical energy, and the element push rod to produce a displacement direction, using the element displacement of push rod to realize various functions of automatic control. Element is returned after the set temperature drop of push rod of the return spring.3. Features:(1) the size is small, occupy the space is little, and the element size, structure is designed according to the need to the workplace.(2) adjust temperature accurate and reliable.(3) no vibration, stable working process.(4) components do not need special maintenance, maintenance.(5) the long service life.4. The main technical performance parameters:(1) the push rod height: thermal element assembly size height shall be determined in accordance with the drawings and technical documents.(2) the push rod displacement: related to the temperature range and size requirements, custom-made ㎜ ~ 40 ㎜ range from 4.(3) temperature range: self-induction temperature cell temperature control order can range from 20 ℃ to 150 ℃.(4) hysteresis: rising curve and the trip itinerary decline curve, there is gap between delay element temperature and element action when parts of the friction between the parts is the cause of hysteresis, hysteresis in the plus or minus 2 ℃ in general.(5) the negative gravity: depending on the element shape dimension, custom-made the load thermal element under load.My company accept custom-made from a wide variety of thermal components, applications can provide solution for customers.Product model images:

An introduction to the heat component of the air vents

Technical parameters:[table]My company's temperature control components to temperature, type, size, push rod stroke, push rod pressure, installation and other accept custom-made.Self-induction tuyere temperature type information application advantagesOne, self-induction temperature type tuyere advantage1, automatic perception blow out air temperature, under the cooling mining (supply air temperature below 17 ℃), and heating conditions (28 ℃ above) formed when different air supply Angle. Ensure air conditioning area rapidly to meet the design requirements, achieve the effect of the environment is comfortable.2, for does not use any electrical equipment, so there's no need to electrical control and maintain daily operation and management of the tuyere can adjust not consume energy.3, tuyere blade Angle adjustment using self-reliance type thermal components, precision, service life is long, generally ensure 30 years of trouble-free operation, reliable in performance.Second, since the motion of several common tuyere temperature type air supply renderingSwirl tuyere air supply rendering:

An introduction to the heat component of the air vents

Side supply air of air supply outlet rendering:

An introduction to the heat component of the air vents

Spread the inverter supply rendering:

An introduction to the heat component of the air vents